• Users Online: 90
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
MINI REVIEW
Year : 2023  |  Volume : 25  |  Issue : 1  |  Page : 8-15

Option appraisal of matrix-assisted laser desorption ionisation time of flight systems for a diagnostic microbiology laboratory


1 Faculty of Biotechnology and Biosciences, School of Medical Science and Technology, Indian Institute of Technology, Kharagpur; Department of Microbiology, Tata Medical Center, Kolkata, West Bengal, India
2 Department of Microbiology, Tata Medical Center, Kolkata, West Bengal, India

Correspondence Address:
Sanjay Bhattacharya
Department of Microbiology, Tata Medical Center, Kolkata - 700 160, West Bengal
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jacm.jacm_4_23

Rights and Permissions

A major challenge for a clinical diagnostic bacteriology/mycology laboratory is to identify the causal microorganism to the species level within a limited time frame. Conventional microbiological techniques such as culture, Gram stain, biochemical tests and molecular tests like 16S rRNA analysis can take days to yield the desired result. Matrix-assisted laser desorption ionisation-time of flight (MALDI-TOF) mass spectrometry (MS) system serves as a potential solution as it can provide accurate identification results within minutes. While several MALDI-TOF MS instruments are in the market, choosing the right system and comparing all the relative pros and cons can be difficult. Our present study focuses on this aspect as we have performed an option appraisal between two leading MALDI-TOF MS instruments, namely the MBT Sirius IVD system (Bruker) and the VITEK-MS system (Biomerieux). We have discussed all the parts of MALDI-TOF systems in detail followed by a cost analysis categorising the total cost into capital and consumable cost which will provide clarity of the estimated budget. We have also discussed the principle involved in organism identification and have compared the two systems concerning technology, accuracy, database, optimal operating conditions, etc. This article aims to provide readers with a better understanding of MALDI-TOF systems and facilitate informed decision-making regarding the acquisition of such systems.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2467    
    Printed217    
    Emailed0    
    PDF Downloaded9    
    Comments [Add]    

Recommend this journal