Journal of The Academy of Clinical Microbiologists

Register      Login

VOLUME 23 , ISSUE 1 ( January-June, 2021 ) > List of Articles

Original Article

Determining the feasibility of constructing a real-time polymerase chain reaction instrument locally: The cost of intellectual property rights and research and development

Saptati Bhattacharjee, Sanjay Bhattacharya

Keywords : Intellectual property rights, low cost, low-middle income countries, real-time polymerase chain reaction, system configuration

Citation Information : Bhattacharjee S, Bhattacharya S. Determining the feasibility of constructing a real-time polymerase chain reaction instrument locally: The cost of intellectual property rights and research and development. J Acad Clin Microbiol 2021; 23 (1):18-23.

DOI: 10.4103/jacm.jacm_45_21

License: CC BY-NC 4.0

Published Online: 16-09-2021

Copyright Statement:  Copyright © 2021; Wolters Kluwer India Pvt. Ltd.


Abstract

BACKGROUND: Real-time polymerase chain reaction (PCR) machines have advanced the field of microbiology by introducing a robust method for high-throughput detection of nucleic acid targets. Unfortunately, these instruments are quite expensive to purchase and maintain, despite containing hardware parts that are relatively inexpensive. AIMS AND OBJECTIVES: We believe that it may be possible to mitigate costs in low- and middleincome countries (LMICs) by building such a PCR instrument from assembled parts. However, the major hindrance is the cost of intellectual property rights (IPRs), associated with research and development (R and D). The aim of this project was to understand the hardware costs, IPR royalties, profit margins, and the cost of R and D associated with PCR instrument manufacturing. MATERIALS AND METHODS: We conducted a review of two PCR machines to examine the differences in their technical and hardware specifications and quantify the cost of assembled parts alone. We also ran a parallel assay using the two machines to understand how the differences in technologies affected assay results. RESULTS AND CONCLUSION: Based on our analysis, we found that assembling a PCR machine using assembled parts can make these instruments more affordable in LMICs. There is a need to have collaboration and agreement between machine licensing, patent, and copyright holders to facilitate this process in LMICs.


PDF Share
  1. Freeman WM, Walker SJ, Vrana KE. Quantitative RT-PCR: Pitfalls and potential. Biotechniques 1999;26:112-22, 124-5.
  2. Heid CA, Stevens J, Livak KJ, Williams PM. Real time quantitative PCR. Genome Res 1996;6:986-94.
  3. Wong ML, Medrano JF. Real-time PCR for mRNA quantitation. Biotechniques 2005;39:75-85.
  4. Tichopad A, Dilger M, Schwarz G, Pfaffl MW. Standardized determination of real-time PCR efficiency from a single reaction set-up. Nucleic Acids Res 2003;31:e122.
  5. Saunders NA. Real-time PCR. Methods Mol Biol 2004;266:191-211.
  6. Espy MJ, Uhl JR, Sloan LM, Buckwalter SP, Jones MF, Vetter EA, et al. Real-time PCR in clinical microbiology: Applications for routine laboratory testing. Clin Microbiol Rev 2006;19:165-256.
  7. Valasek MA, Repa JJ. The power of real-time PCR. Adv Physiol Educ 2005;29:151-9.
  8. Higuchi R, Dollinger G, Walsh PS, Griffith R. Simultaneous amplification and detection of specific DNA sequences. Biotechnology (N Y) 1992;10:413-7.
  9. Ginzinger DG. Gene quantification using real-time quantitative PCR: An emerging technology hits the mainstream. Exp Hematol 2002;30:503-12.
  10. Spectrolab. PMT vs. CCD Based Systems. (Spectrolab Systems Website). Available from: http://www.spectrolabsystems.net/products/analytical-instruments/arcspark-optical-emission-spectroscopy-oes/pmt-vs-ccd-based-systems.html. [Last accessed on 2015 Jun 16].
  11. Maher, Brendan. How It Works: Real-Time PCR (The Scientist Magazine Website); December 1, 2006. Available from: http://www.the-scientist.com/?articles.view/articleNo/24568/title/How-it-Works--Real-Time-PCR/. [Last accessed on 2015 Jun 16].
  12. Lee DS. Real-time PCR machine system modeling and a systematic approach for the robust design of a real-time PCR-on-a-chip system. Sensors (Basel) 2010;10:697-718.
  13. Applied Biosystems. 7500/7500 Fast Real-Time PCR System: Standard Curve Experiments; 2007. Available from: https://www3.appliedbiosystems.com/cms/groups/mcb_support/documents/generaldocuments/cms_050329.pdf. [Last accessed on 2015 Jun 04].
  14. Applied Biosystems. 7500/7500 Fast Real-Time PCR Systems: System Maintenance; 2008. Available from: https://tools.lifetechnologies.com/content/sfs/manuals/4387777d.pdf. [Last accessed on 2015 Jun 04].
  15. Applied Biosystems. 7500/7500 Fast Real-Time PCR System: Relative Standard Curve and Comparative CT Experiments; 2007. Available from: http://www3.appliedbiosystems.com/cms/groups/mcb_support/documents/generaldocuments/cms_050330.pdf. [Last accessed on 2015 Jun 04].
  16. Applied Biosystems. 7500/7500 Fast Real-Time PCR System: A Real Fast and Real Versatile Approach to Real-Time PCR; 2004. Available from: http://www.gene-quantification.com/abi7500.pdf. [Last accessed on 2015 Jun 04].
  17. Tellurex Corporation. About Thermoelectric Cooling. (University of Toronto) 2006. Available from: http://www.physics.utoronto.ca/~phy326/xrf/APPENDIX%20C.pdf. [Last accessed on 2015 Jun 17].
  18. Rotor-Gene. Rotor-Gene Q – Pure Detection; March 2011. Available from: http://www.iabio.cz/media/pdf/Rotor-Gene.pdf. [Last accessed on 2015 Jun 05].
  19. Rotor-Gene. User Manual; February 2012. Available from: http://www.biozentrum.unibas.ch/fileadmin/redaktion/Forschung/Research_Groups/BF/instruments/Rotorgene_Manual.pdf. [Last accessed on 2015 Jun 05].
  20. Qiagen. Rotorgene Simulation. Available from: https://www.qiagen.com/media/product-tools/flash/RotorGeneQ/360/index.html. [Last accessed on 2015 Jun 05].